Life testing of LSM-YSZ composite electrodes under reversing-current operation

Journal article published in 2013 by Gareth A. Hughes, Kyle Yakal-Kremski, Scott A. Barnett
This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Durability testing of solid oxide cell electrodes in reversing-current and constant-current operation modes is presented. (La0.8Sr0.2)0.98MnO3-δ-Zr0.84Y0.16O2-γ (LSM-YSZ) symmetric cells were tested at 800 °C in air with current densities of 0.5 and 1.5 A cm(-2), with current cycle periods of 1 and 12 h. A continuous increase in both ohmic and polarization resistance was observed, via Electrochemical Impedance Spectroscopy (EIS), for cells tested with a reversing current of 1.5 A cm(-2), whereas cells tested at 0.5 A cm(-2) showed no measurable resistance increase. The resistance degradation was explained by delamination in the electrode, observed by post-test Scanning Electron Microscopy (SEM), near the interface with the electrolyte for the 1.5 A cm(-2) cells, but not for those tested at 0.5 A cm(-2). Current cycle period also impacted the degradation observed at 1.5 A cm(-2): both the rate of resistance increase and the extent of post-test delamination decreased on going from constant current mode to a 12 h period to a 1 h period. The results indicate that lower current densities and reversing-current operation are desirable to maximize the lifetime of solid oxide cells.