Royal Society of Chemistry, Analyst, 24(138), p. 7294
DOI: 10.1039/c3an01540h
Full text: Download
Single-channel electrophysiology with lipid bilayer systems requires ion channel expression, purification from cell culture, and reconstitution in proteoliposomes for delivery to a planar bilayer. Here we demonstrate that single-channel current measurements of the potassium channels KcsA and hERGS5-S6 can be obtained by direct insertion in interdroplet lipid bilayers from microliters of a cell-free expression medium.