Dissemin is shutting down on January 1st, 2025

Published in

Lippincott, Williams & Wilkins, Innovations:Technology and Techniques in Cardiothoracic and Vascular Surgery, 2(13), p. 104-107, 2018

DOI: 10.1177/155698451801300205

Lippincott, Williams & Wilkins, Innovations:Technology and Techniques in Cardiothoracic and Vascular Surgery, 2(13), p. 104-107, 2018

DOI: 10.1097/imi.0000000000000478

Links

Tools

Export citation

Search in Google Scholar

Clinical Experience in Minimally Invasive Cardiac Surgery With Virtually Wall-Less Venous Cannulas:

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Objective Inadequate peripheral venous drainage during minimally invasive cardiac surgery (MICS) is a challenge and cannot always be solved with increased vacuum or increased centrifugal pump speed. The present study was designed to assess the benefit of virtually wall-less transfemoral venous cannulas during MICS. Methods Transfemoral venous cannulation with virtually wall-less cannulas (3/8″ 24F 530–630-mm ST) was performed in 10 consecutive patients (59 ± 10 years, 8 males, 2 females) undergoing MICS for mitral (6), aortic (3), and other (4) procedures (combinations possible). Before transfemoral insertion of wall-less cannulas, a guidewire was positioned in the superior vena cava under echocardiographic control. The wall-less cannula was then fed over the wire and connected to a minimal extracorporeal system. Vacuum assist was used to reach a target flow of 2.4 l/min per m2 with augmented venous drainage at less than −80 mm Hg. Results Wall-less venous cannulas measuring either 630 mm (n = 8) in length or 530 mm (n = 2) were successfully implanted in all patients. For a body size of 173 ± 11 cm and a body weight of 78 ± 26 kg, the calculated body surface area was 1.94 ± 0.32 m2. As a result, the estimated target flow was 4.66 ± 0.78 l/min, whereas the achieved flow accounted for 4.98 ± 0.69 l/min (107% of target) at a vacuum level of 21.3 ± 16.4 mm Hg. Excellent exposure and “dry” intracardiac surgical field resulted. Conclusions The performance of virtually wall-less venous cannulas designed for augmented peripheral venous drainage was tested in MICS and provided excellent flows at minimal vacuum levels, confirming an increased performance over traditional thin wall cannulas. Superior results can be expected for routine use.