Published in

Optica, Biomedical Optics Express, 11(5), p. 4024, 2014

DOI: 10.1364/boe.5.004024

Links

Tools

Export citation

Search in Google Scholar

Real-time measurement of alveolar size and population using phase contrast x-ray imaging

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Red circle
Preprint: archiving forbidden
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Herein a propagation-based phase contrast x-ray imaging technique for measuring particle size and number is presented. This is achieved with an algorithm that utilizes the Fourier space signature of the speckle pattern associated with the images of particles. We validate this algorithm using soda-lime glass particles, demonstrating its effectiveness on random and non-randomly packed particles. This technique is then applied to characterise lung alveoli, which are difficult to measure dynamically in vivo with current imaging modalities due to inadequate temporal resolution and/or depth of penetration and field-of-view. We obtain an important result in that our algorithm is able to measure changes in alveolar size on the micron scale during ventilation and shows the presence of alveolar recruitment/de-recruitment in newborn rabbit kittens. This technique will be useful for ventilation management and lung diagnostic procedures.