Published in

Medical Imaging 2001: Physiology and Function from Multidimensional Images

DOI: 10.1117/12.428143

Links

Tools

Export citation

Search in Google Scholar

Resolution of the spectral technique in kinetic modeling

Proceedings article published in 2001 by Chaincy Kuo ORCID, Bryan W. Reutter, Ronald H. Huesman
This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Red circle
Preprint: archiving forbidden
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Physiologic systems can be represented by compartmental models which describe the uptake of radio-labeled tracers from blood to tissue and their subsequent washout. Arterial and venous time-activity curves from isolated heart experiments are analyzed using spectral analysis, in which the impulse response function is represented by a sum of decaying exponentials. Resolution and uniqueness tests are conducted by synthesizing isolated heart data with predefined compartmental models, adding noise, and applying the spectral analysis technique. Venous time-activity curves are generated by convolving a typical arterial input function with the predefined spectrum. The coefficients of a set of decaying exponential basis functions are determined using a non-negative least squares algorithm, and results are compared with the predefined spectrum. The uniqueness of spectral method solutions is investigated by computing model covariance matrices, using error propagation and prior knowledge of noise distributions. Coupling between model parameters is illustrated with correlation matrices.