Statistical analysis of the temporal single-photon response of superconducting nanowire single photon detection

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Counting rate is a key parameter of superconducting nanowire single photon detectors (SNSPD) and is determined by the current recovery time of an SNSPD after a detection event. We propose a new method to study the transient detection efficiency (DE) and pulse amplitude during the current recovery process by statistically analyzing the single photon response of an SNSPD under photon illumination with a high repetition rate. The transient DE results match well with the DEs deduced from the static current dependence of DE combined with the waveform of a single-photon detection event. This proves that the static measurement results can be used to analyze the transient current recovery process after a detection event. The results are relevant for understanding the current recovery process of SNSPDs after a detection event and for determining the counting rate of SNSPDs. ; Comment: 11 pages,4 figures