Published in

Elsevier Masson, Agricultural and Forest Meteorology, (236), p. 87-99

DOI: 10.1016/j.agrformet.2017.01.009

Links

Tools

Export citation

Search in Google Scholar

Evaluation of eddy covariance latent heat fluxes with independent lysimeter and sapflow estimates in a Mediterranean savannah ecosystem

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

We evaluated the underlying causes of differences between latent heat (LE) fluxes measured with two enclosed-path eddy covariance systems (EC) at two measurement levels and independent estimates in an open oak-tree grass savannah over almost one year. Estimates of LE of the well-stablished underlying grass by replicated weighable tension-controlled lysimiters (LELys) provided a robust baseline against which to compare EC LE measured at 1.6mabove ground (LE 1.6). Similarly and at the ecosystem level, LE up-scaled using independent measurements (LEupscaled = sap flow+ lysimeter) was benchmarked with 3 EC-derived LE estimates: 1) LE measured by a EC tower at 15mabove ground (LE 15), 2) LE 15 adjusted to close the energy balance by using the Bowen ratio method (LEBowen = (Rn −G)/(1 +b)), and 3) LE derived from the energy budget residual (LEresidual = Rn −G−H 15). The sensitivity of EC LE to the correction method applied (i.e. corrections for low-pass filtering effects on water vapor fluctuations and the so-called angle-of-attack correction) and its impact on the energy balance closure (EBC) were also evaluated. Comparison of EC LE between 1.6m- and 15 m-heights showed that grass dominated annual evaporative loss from 69 to 87% depending upon the spectral correction method applied. Results revealed substantial underestimation of LE 1.6 (up to 35%) compared to LELys, which mostly occurred during the growing season. However those differences were remarkably lower when likening LE 15 versus LEupscaled (14%) suggesting that the dampening of the water vapor fluctuations due to low-pass filtering effects is more pronounced near the surface. Interestingly, a diagnostic evaluation of the errors with a random forest model showed that differences followed quite structured patterns and were associated with certain atmospheric conditions: turbulent mixing deficiencies and or stable atmospheric stratification. In addition, the model showed that differences increased with increasing relative humidity (RH) and soil moisture. Our results revealed that the degree of EBC is highly sensitive to the flux correction method applied, in particular when correcting for flow distortion effects. Typically, turbulent fluxes fell below the measured available energy (slope 0.92) but the slope switched abruptly when the angle-of-attack correction was applied (slope 1.07). Consistent with the EBC, independent LE estimates matched well with LEBowen and the EBC gap decreased when LEupscaled was used (slope 0.96). The use of independent estimates of LE together with machine learning methods are proposed as a powerful means to diagnose the complexity behind LE errors and give insights into the energy imbalance problem. In addition to inherent randomness of EC LE data, accounting for uncertainties associated with the appropriateness of the correction method applied is highly recommended.