Published in

Lippincott, Williams & Wilkins, Journal of Bone and Joint Surgery, 5(98), p. 356-362, 2016

DOI: 10.2106/jbjs.o.00127

Links

Tools

Export citation

Search in Google Scholar

Effect of a Cast on Short-Term Reproducibility and Bone Parameters Obtained from HR-pQCT Measurements at the Distal End of the Radius

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

BACKGROUND: High-resolution peripheral quantitative computed tomography (HR-pQCT) is a promising tool to assess the fracture-healing process at the microscale in vivo. Since casts are often used during fracture treatment, they might affect the assessment of bone density, microarchitectural, and biomechanical parameters and the short-term reproducibility of those parameters, e.g., as a result of beam-hardening. The aim of this study was to assess the effect of a plaster-of-Paris and/or fiberglass cast on bone parameters and on the short-term reproducibility of the HR-pQCT measurements of those parameters. METHODS: The effects of a cast on HR-pQCT-derived bone parameters were evaluated by comparing HR-pQCT scans of fifteen human cadaveric distal radial specimens from one male and fourteen female donors (median age, eighty-four years [range, sixty-two to ninety years] at the time of death) in three conditions: with a plaster-of-Paris cast, with a fiberglass cast, or without a cast. Short-term reproducibility was assessed using duplicate scans of the distal end of the radius in sixteen healthy volunteers without a fracture (nine men and seven women with a median age of twenty-six years; range, twenty-two to thirty-nine years) while wearing and not wearing a fiberglass cast. RESULTS: Compared with measurements made with no cast, the plaster-of-Paris cast introduced a systematic error in the bone parameters ranging from -2.6% in trabecular separation to -9.8% in cortical thickness. Bone parameters were affected only marginally by fiberglass, with errors between -0.6% and -1.6% in trabecular separation and cortical thickness, respectively. Short-term reproducibility with a fiberglass cast was similar to that with no cast: approximately 1% for bone density parameters, 4% to 5% for microarchitectural parameters, and 3% to 4% for biomechanical parameters. CONCLUSIONS: A plaster-of-Paris cast has a considerable effect on HR-pQCT measurements. A fiberglass cast only marginally affects the bone parameters, and the short-term reproducibility of HR-pQCT measurements in patients with a fiberglass cast is comparable with that in patients without a cast. In studies on fracture-healing using HR-pQCT, a fiberglass cast is desirable if immobilization is indicated. The use of a plaster-of-Paris cast should be avoided if possible; however, if not avoidable, corrections after the scan are desirable to adjust for the error introduced in the bone parameters.