Wiley, Magnetic Resonance in Medicine, 1(67), p. 269-277, 2011
DOI: 10.1002/mrm.22997
Full text: Download
Longitudinal and transverse rotating-frame relaxation time constants, T(1) (ρ) and T(2) (ρ) , have previously been successfully applied to detect gene therapy responses and acute stroke in animal models. Those experiments were performed with continuous-wave irradiation or with frequency-modulated pulses operating in an adiabatic regime. The technique called Relaxation Along a Fictitious Field (RAFF) is a recent extension of frequency-modulated rotating-frame relaxation methods. In RAFF, spin locking takes place along a fictitious magnetic field, and the decay rate is a function of both T(1ρ) and T(2ρ) processes. In this work, the time constant characterizing water relaxation with RAFF (T(RAFF) ) was evaluated for its utility as a marker of response to gene therapy in a rat glioma model. To investigate the sensitivity to early treatment response, we measured several rotating-frame and free-precession relaxation time constants and the water apparent diffusion coefficients, and these were compared with histological cell counts in 8 days of treated and control groups of animals. T(RAFF) was the only parameter exhibiting significant association with cell density in three different tumor regions (border, intermediate, and core tissues). These results indicate that T(RAFF) may provide a marker to identify tumors responding to treatment.