Published in

College of American Pathologists, Archives of Pathology & Laboratory Medicine, 10(139), p. 1276-1280, 2015

DOI: 10.5858/arpa.2014-0543-cp

Links

Tools

Export citation

Search in Google Scholar

Marked Variability in Reported Minimal Residual Disease Lower Level of Detection of 4 Hematolymphoid Neoplasms: A Survey of Participants in the College of American Pathologists Flow Cytometry Proficiency Testing Program

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Red circle
Preprint: archiving forbidden
Red circle
Postprint: archiving forbidden
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Context Flow cytometry is often applied to minimal residual disease (MRD) testing in hematolymphoid neoplasia. Because flow-based MRD tests are developed in the laboratory, testing methodologies and lower levels of detection (LODs) are laboratory dependent. Objectives To broadly survey flow cytometry laboratories about MRD testing in laboratories, if performed, including indications and reported LODs. Design Voluntary supplemental questions were sent to the 549 laboratories participating in the College of American Pathologists (CAP) FL3-A Survey (Flow Cytometry—Immunophenotypic Characterization of Leukemia/Lymphoma) in the spring of 2014. Results A total of 500 laboratories (91%) responded to the supplemental questions as part of the FL3-A Survey by April 2014; of those 500 laboratories, 167 (33%) currently perform MRD for lymphoblastic leukemia, 118 (24%) for myeloid leukemia, 99 (20%) for chronic lymphocytic leukemia, and 91 (18%) for plasma cell myeloma. Other indications include non-Hodgkin lymphoma, hairy cell leukemia, neuroblastoma, and myelodysplastic syndrome. Most responding laboratories that perform MRD for lymphoblastic leukemia reported an LOD of 0.01%. For myeloid leukemia, chronic lymphocytic leukemia, and plasma cell myeloma, most laboratories indicated an LOD of 0.1%. Less than 3% (15 of 500) of laboratories reported LODs of 0.001% for one or more MRD assays performed. Conclusions There is major heterogeneity in the reported LODs of MRD testing performed by laboratories subscribing to the CAP FL3-A Survey. To address that heterogeneity, changes to the Flow Cytometry Checklist for the CAP Laboratory Accreditation Program are suggested that will include new requirements that each laboratory (1) document how an MRD assay's LOD is measured, and (2) include the LOD or lower limit of enumeration for flow-based MRD assays in the final diagnostic report.