Published in

American Association of Neurological Surgeons, Journal of Neurosurgery: Spine, 2(10), p. 129-132, 2009

DOI: 10.3171/2008.11.spi0817677

Links

Tools

Export citation

Search in Google Scholar

Engineering patient-specific drill templates and bioabsorbable posterior cervical plates: a feasibility study

Distributing this paper is prohibited by the publisher
Distributing this paper is prohibited by the publisher

Full text: Unavailable

Red circle
Preprint: archiving forbidden
Red circle
Postprint: archiving forbidden
Question mark in circle
Published version: policy unknown
Data provided by SHERPA/RoMEO

Abstract

Object The authors describe a method of using computer models to generate customized cervical implants. A promising yet challenging technique in cervical spine surgery involves the use of pedicle screws to assist with posterior instrumentation. Surrounding anatomical structures such as the vertebral arteries and cervical nerve roots present challenges for safe screw placement; however, the use of computer-generated templates seems to be a promising method to assist with placement. In this study, the authors explore the use of computer-generated templates and introduce their methods for creating custom, bioabsorbable posterior cervical implants. Methods The cervical spines (C2–T1) from 4 cadavers were scanned with volumetric CT. Using commercially available software, the authors generated volumetric models of a cervical drill template and the mold for a cervical plate spanning a desired number of vertebrae. The computer generated models of the cervical drill template and cervical plate mold were converted into physical models using a rapid prototyping machine. The biopolymer polylactic acid resin was heated to 250°C and resolidified to form thin ~ 5-mm-thick plates. The newly formed plates were reheated to 60°C and cast on the cervical mold. Results The resulting translucent plates were found on visual inspection to have a secure lock-and-key fit on the original cadaver spine, and the techniques used were robust and reproducible. The process described in this brief report provides the background to proceed with development and testing of these patient-absorbable templates. Conclusions The creation and use of patient-specific bioabsorbable posterior cervical plates in conjunction with multilevel drill templates appear promising. Additional feasibility studies are planned, and in vitro studies are required to determine the safety and efficacy of using patient-specific drill templates and converting them into bioabsorbable implants.