Published in

American Physiological Society, American Journal of Physiology - Heart and Circulatory Physiology, 6(292), p. H2589-H2597

DOI: 10.1152/ajpheart.01336.2006

Links

Tools

Export citation

Search in Google Scholar

Ventricular fibrillation in myopathic human hearts: mechanistic insights from in vivo global endocardial and epicardial mapping

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Ventricular fibrillation (VF) is an important cause of sudden cardiac death and cardiovascular mortality in patients with cardiomyopathy. Although it was generally believed that chaotic reentrant wavefronts underlie VF in humans, there is emerging evidence of spatiotemporal organization during early VF. The mechanism of this organization of electrical activity in early VF is unknown in myopathic hearts. We studied early VF in vivo, intraoperatively in five cardiomyopathic patients. Simultaneous electrograms were obtained from the epicardium and endocardium in left ventricular cardiomyopathy and from the endocardium in right ventricular myopathy. The Hilbert transform was used to derive the phase of the electrograms. Rotors were identified by isolating phase singularity points. Rotors were present in all of the myopathic hearts studied during VF and cumulatively lasted a mean of 3.2 ± 2.0 s of the 7.0 ± 4.0 s of the VF segments analyzed. For each surface mapped, 3.6 ± 2.9 rotors were identified for the duration mapped. The average number of cycles completed by these rotors was 4.9 ± 4.9. The longest rotor lasted 10.2 ± 6.2 rotations and lasted 2.0 ± 1.2 s. The rotors on the endocardium had a cycle length of 192 ± 33 ms compared with 220 ± 15 ms on the epicardium ( P = 0.08). There is centrifugal activation of electrical activity from these rotors, and they give rise to domains that activate at faster rates with evidence of conduction block at the border with slower domains. These rotors frequently localized to border regions of myocardium with bipolar electrogram amplitude of <0.5 mV. The organization of electrical activity during early VF in myopathic human hearts is characterized by wavefronts emanating from a few rotors.