Published in

BioMed Central, Radiation Oncology, 1(10), 2015

DOI: 10.1186/s13014-015-0451-3

Links

Tools

Export citation

Search in Google Scholar

Regional hyperthermia of the abdomen, a pilot study towards the treatment of peritoneal carcinomatosis

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Abstract Background Peritoneal carcinomatosis occurs in different cancer subtypes and is associated with a dismal prognosis. Some doubts remain whether the whole abdomen can be treated by regional hyperthermia, therefore we analyzed feasibility conducting a pilot study. Methods A simulation of the abdominopelvic heat distribution in 11 patients with peritoneal carcinomatosis was done using the HyperPlan software and the SIGMA-60 and SIGMA-Eye applicators. Tissue-specific region-related electrical and thermal parameters were used to solve the Maxwell’s equations and the bioheat-transfer equation. Three-dimensional specific absorption rate (SAR) distributions and, additionally, estimated region-related perfusion rates were used to solve the bioheat-transfer equation. The predicted SAR and temperature distributions were compared with minimally invasive measurements in pelvic reference points. Results In 11 patients (7 of them treated in the SIGMA-60 and 4 in the SIGMA-Eye applicator) the measured treatment variables (SAR, temperatures in the pelvic reference points) indicated that the heated volumes were higher for the SIGMA-Eye applicator. The mean computed abdominal SARs were less for the SIGMA-Eye (33 versus 44 W/kg). Nevertheless, the temperature distributions in the abdomen (peritoneal cavity) were more homogeneous in the SIGMA-Eye applicator as compared to the SIGMA-60 as indicated by higher values of T 90 (mean 40.2 versus 38.2 °C) and T 50 (mean 41.1 versus 40.2 °C), while the maximum temperatures were similar (in the range 41 to 43 °C). Even though the mean abdominal SAR was lower in the SIGMA-Eye, the heat distribution covered a larger volume of the abdomen (in particular the upper abdomen). For the SIGMA-60 applicator the achieved T 90 appeared to be limited between 41 and 42 °C, for the SIGMA Eye applicator more effective T 90 in the range 42 to 43 °C were obtained. Conclusion Our results suggest that an adequate heating of the abdomen and therefore abdominal regional hyperthermia in PC patients appears feasible. The SIGMA-Eye applicator appears to be superior compared to the SIGMA-60 applicator for abdominal hyperthermia.