Air heating of passive houses in cold climates: Investigation using detailed dynamic simulations

Journal article published in 2014 by Laurent Georges ORCID, Monica Berner, Hans Martin Mathisen
This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Red circle
Postprint: archiving forbidden
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

The passive house (PH) standard was originally defined for Central Europe and has subsequently been applied to many cold climate countries. In these conditions, the relation between this standard and the air heating (AH) is not clear while both concepts are usually associated. Furthermore, the AH provides a way to simplify the space-heating distribution system. The present contribution investigates the feasibility of the AH concept in PH along with its challenges in terms of thermal dynamics: the magnitude of the AH temperature needed, the temperature difference between rooms, the impact of internal gains, the influence of thermal losses from ventilation ducts and the AH control. This is performed using detailed dynamic simulations (TRNSYS) on a typical detached house typology. Practically, four cold climate zones are considered as well as different insulation levels and construction materials. Results show limitations related to a centralized AH as well as provide guidelines for a consistent AH design in cold climates. In addition, a simple analytical method used for the design of German PH is tested and proved accurate enough to estimate the maximal AH temperature during the heating season. ; (c) 2014 Elsevier Ltd. All rights reserved. This is the authors' accepted and refereed manuscript to the article. Locked until April 2014 due to copyright restriction.