Published in

Wiley, Journal of Magnetic Resonance Imaging, 4(26), p. 1020-1032, 2007

DOI: 10.1002/jmri.21127

Links

Tools

Export citation

Search in Google Scholar

Gadobenate dimeglumine-enhanced MR angiography: Diagnostic performance of four doses for detection and grading of carotid, renal, and aorto-iliac stenoses compared to digital subtraction angiography

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

PURPOSE: To determine the diagnostic performance of contrast-enhanced MR angiography (CE-MRA) with four doses of gadobenate dimeglumine for detection of significant steno-occlusive disease of the carotid, renal, and pelvic vasculature. MATERIALS AND METHODS: Eighty-four patients with suspected disease of the renal (n = 16), pelvic (n = 41), or carotid (n = 27) arteries underwent CE-MRA (3D-spoiled gradient-echo sequences) at 1.5T. CE-MRA was performed with gadobenate dimeglumine at 0.025, 0.05, 0.1, or 0.2 mmol/kg (23, 24, 19, and 18 patients, respectively) administered at 2 mL/sec. Accuracy, sensitivity, specificity, and positive and negative predictive values (PPV and NPV, respectively) for detection of significant disease (>50% stenosis or occlusion for renal/pelvic arteries; >70% stenosis or occlusion for carotid arteries) was determined by three fully blinded, independent radiologists using conventional digital subtraction angiography (DSA) as reference standard. All comparisons were tested statistically (ANOVA, chi-square, and Mantel-Haenszel tests as appropriate) and reader agreement (kappa) was assessed. RESULTS: Values for accuracy, sensitivity, specificity, PPV, and NPV on CE-MRA were consistently higher for 0.1 mmol/kg gadobenate dimeglumine (accuracy = 95.2-97.3%, sensitivity = 84.2% (all readers), specificity = 96.9-99.2%, PPV = 80.0-94.1%, NPV = 97.6-97.7%). The greater accuracy of the 0.1 mmol/kg dose was significant (P /=0.58), with the highest percent agreement (85.7%) noted for the 0.1 mmol/kg dose. CONCLUSION: Significantly better diagnostic performance on CE-MRA of the renal, pelvic, and carotid arteries is achieved with a gadobenate dimeglumine dose of 0.1 mmol/kg bodyweight. (c) 2007 Wiley-Liss, Inc.