Dissemin is shutting down on January 1st, 2025

Published in

Lippincott, Williams & Wilkins, European Journal of Gastroenterology & Hepatology, 9(26), p. 941-948, 2014

DOI: 10.1097/meg.0000000000000132

Lippincott, Williams & Wilkins, European Journal of Gastroenterology & Hepatology, 1(27), p. 113

DOI: 10.1097/meg.0000000000000265

Links

Tools

Export citation

Search in Google Scholar

Accuracy of GastroPanel for the diagnosis of atrophic gastritis

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Background It has been suggested that GastroPanel might be a useful tool for the diagnosis of chronic atrophic gastritis (CAG) measuring four biomarkers in blood: basal gastrin-17 (G17), pepsinogen I and II (PGI and PGII), and Helicobacter pylori antibodies. Aim To determine the accuracy of GastroPanel for the diagnosis of CAG. Methods This was a prospective, blinded, multicenter study that included dyspeptic patients. G17, PGI, and PGII were determined by enzyme immunoassays. Three antrum and two corpus biopsies were obtained for standard histological analysis and rapid urease test. Biopsies were analyzed by a single blinded expert pathologist. Results Ninety-one patients were included (77% women, mean age 44 years, 51% H. pylori positive, 17% with CAG). G17 was reduced in patients with antrum CAG (5.4 vs. 13.4 pmol/l; P<0.01) and increased in patients with corpus CAG (11 vs. 24 pmol/l; P<0.05), but its accuracy was only acceptable in the case of corpus localization [ area under the receiver operating characteristic curve (AUC), 74%]; PGII difference was almost statistically significant only when testing for corpus atrophy (33 vs. 21 g/l; P=0.05; AUC=72%). The PGI and PGI/PGII ratio showed no significant differences (AUCs were all unacceptably low). Helicobacter pylori antibody levels were higher in H. pylori-infected patients (251 vs. 109 EIU, P=0.01; AUC=70). The accuracy of GastroPanel for the diagnosis of CAG was as follows: sensitivity 50%; specificity 80%; positive 25% and negative 92% predictive values; and positive 2.4 and negative 0.6 likelihood ratios. Conclusion GastroPanel is not accurate enough for the diagnosis of CAG; thus, its systematic use in clinical practice cannot be recommended. (C) 2014 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.