Doped silicon and NIS junctions for bolometer applications

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Red circle
Postprint: archiving forbidden
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

We discuss the performance, of a normal metal hot electron bolometer (NHEB) that we have measured at 0.3 K. We found that the noise equivalent power was limited by the amplifier noise. To improve the NHEB power response and to make it more robust and reliable we propose to substitute the normal metal with heavily doped silicon. The heavily doped silicon behaves like a metal with lower carrier concentration and has a smaller electron–phonon thermal coupling. We have fabricated superconductor-doped silicon-superconductor contacts (S-Sm-S) and we have used them as thermometers and coolers.