Dissemin is shutting down on January 1st, 2025

Published in

Elsevier, International Journal of Surgery Case Reports, (21), p. 78-82, 2016

DOI: 10.1016/j.ijscr.2016.02.035

Links

Tools

Export citation

Search in Google Scholar

Successful treatment of recurrent carotid-in-stent restenosis and drug-eluting balloon failure with a coronary bioresorbable vascular scaffold: a case report

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Red circle
Postprint: archiving forbidden
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Introduction: Carotid in-stent restenosis is associated with substantial risk of recurrent restenosis, even after drug-eluting balloon usage. Presentation of case: We hereby report the case of a patient with recurrent carotid in-stent restenosis and drug-eluting balloon failure treated with a coronary bioresorbable vascular scaffold, achieving a satisfactory acute and long-term result, as disclosed by duplex ultrasound scan performed more than 1 year after the procedure. Discussion/conclusion: While awaiting for external validation, this clinical vignette supports expanding the armamentarium of endovascular specialists focusing on carotid artery disease, while providing further proof of the safety and efficacy of current bioresorbable vascular scaffolds.