Published in

Wiley, Journal of ultrasound in medicine, 8(18), p. 553-558, 1999

DOI: 10.7863/jum.1999.18.8.553

Links

Tools

Export citation

Search in Google Scholar

Flow changes in forearm arteries after elevating the radial forearm flap: Prospective study using color duplex imaging

Journal article published in 1999 by A. Talegón Meléndez, G. Ciria Lloréns, T. Gómez Cía, A. Mayo Iscar ORCID
This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

The aim of the present study was to assess the changes in flow patterns of forearm arteries produced by excision of the radial artery when harvesting the radial forearm flap. A prospective study using color duplex imaging for quantitative flow measurements was accomplished in 11 patients. After raising the radial flap, the forearm flow tended to increase overall, the ulnar (P = 0.04), the posterior interosseous (P = 0.003), and the anterior interosseous (P = 0.003) arteries being responsible for this tendency. Therefore, harvesting of a radial flap must not be considered as causing vascular morbidity in terms of blood supply to the hand.