Published in

IOP Publishing, Chinese Physics C, 7(35), p. 638-641, 2011

DOI: 10.1088/1674-1137/35/7/008

Links

Tools

Export citation

Search in Google Scholar

A study of the active thermal control for the high energy detector on the HXMT

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

A thermal control system (TCS) based on the resistance heating method is designed for the High Energy Detector (HED) on the Hard X-ray Modulation Telescope (HXMT). The ground-based experiments of the active thermal control for the HED with the TCS are performed in the ambient temperature range from −15 to 20°C by utilizing the pulse width to monitor the interior temperature of a NaI(Tl) crystal. Experimental results show that the NaI(Tl) crystal's interior temperature is from 17.4 to 21.7°C when the temperature of the PMT shell is controlled within (20±3)°C with the TCS in the interesting temperature range, and the energy resolution of the HED is maintained at 16.2% @122 keV, only a little worse than that of 16.0% obtained at 20°C. The average power consumption of the TCS for the HED with a low-emissivity shell is about 4.3 W, which is consistent with the simulation.