Published in

2013 Constantinides International Workshop on Signal Processing (CIWSP 2013)

DOI: 10.1049/ic.2013.0020

Links

Tools

Export citation

Search in Google Scholar

Ultrasound Video Despeckle Filtering for High Efficiency Video Coding in M-Health systems

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Mobile-Health (m-health) medical video communication systems need to communicate ultrasound video of adequate diagnostic quality for remote diagnosis and care. In this study, we demonstrate how ultrasound video noise reduction, employed as a pre-processing step, used in conjunction with High Efficiency Video Coding (HEVC), can significantly improve diagnostic quality at considerably lower bitrate demands than conventional H.264/AVC source encoding. Three video despeckle filters were investigated, namely: linear filtering (DsFlsmv), hybrid median filtering (DsFhmedian), and speckle reducing anisotropic diffusion (DsFsrad). The methods were tested using ten atherosclerotic plaque ultrasound videos. Speckle filtering was applied at a frame-level basis. Experimental results were obtained using both subjective (by two clinical experts) and objective video quality assessment. The best achieving despeckle filter was DsFlsmv followed closely by DsFhmedian. In both cases, the filters provided for increased clinical performance while associated with significant bitrate demands reductions.