Cross-Vendor evaluation of key user-defined clinical decision support capabilities: A scenario-based assessment of certified electronic health records with guidelines for future development.

Journal article published in 2015 by Allison B. McCoy ORCID, Adam Wright, Dean F. Sittig
This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Abstract Objective Clinical decision support (CDS) is essential for delivery of high-quality, cost-effective, and safe healthcare. The authors sought to evaluate the CDS capabilities across electronic health record (EHR) systems. Methods We evaluated the CDS implementation capabilities of 8 Office of the National Coordinator for Health Information Technology Authorized Certification Body (ONC-ACB)-certified EHRs. Within each EHR, the authors attempted to implement 3 user-defined rules that utilized the various data and logic elements expected of typical EHRs and that represented clinically important evidenced-based care. The rules were: 1) if a patient has amiodarone on his or her active medication list and does not have a thyroid-stimulating hormone (TSH) result recorded in the last 12 months, suggest ordering a TSH; 2) if a patient has a hemoglobin A1c result >7% and does not have diabetes on his or her problem list, suggest adding diabetes to the problem list; and 3) if a patient has coronary artery disease on his or her problem list and does not have aspirin on the active medication list, suggest ordering aspirin. Results Most evaluated EHRs lacked some CDS capabilities; 5 EHRs were able to implement all 3 rules, and the remaining 3 EHRs were unable to implement any of the rules. One of these did not allow users to customize CDS rules at all. The most frequently found shortcomings included the inability to use laboratory test results in rules, limit rules by time, use advanced Boolean logic, perform actions from the alert interface, and adequately test rules. Conclusion Significant improvements in the EHR certification and implementation procedures are necessary.