Published in

Institute of Electrical and Electronics Engineers, IEEE Transactions on Nuclear Science, 2(60), p. 662-667, 2013

DOI: 10.1109/tns.2012.2231097

Links

Tools

Export citation

Search in Google Scholar

The Potential of Using Li-Ion Batteries for Radiation Detection

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

This work describes the measurement of the change in current of two types of Li-ion batteries, both commercial off-the-shelf and in-house-assembled coin cells, under radiation exposure. The discharging batteries were irradiated with a neutron beam with a 30-mm diameter (adjustable to 10 mm and 5 mm) using the Ohio State University Research Reactor and was measured for the change of electric current with a Keithley SourceMeter. We have observed an increase in current when the batteries were exposed to gamma rays and a decrease in current when only thermal neutrons were applied. We discussed the mechanisms that are responsible for inducing such changes, including the electrode polarization caused by irradiation. The immediate application of a single coin cell in a current mode can be a small neutron or gamma-beam monitor or a near-core flux monitor in a high-flux environment.