Dissemin is shutting down on January 1st, 2025

Published in

BioMed Central, BMC Medical Informatics and Decision Making, 1(11), 2011

DOI: 10.1186/1472-6947-11-29

Links

Tools

Export citation

Search in Google Scholar

Does the implementation of an electronic prescribing system create unintended medication errors? A study of the sociotechnical context through the analysis of reported medication incidents

Journal article published in 2011 by Sabi Redwood, Anna Rajakumar, James Hodson, Jamie J. Coleman ORCID
This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Abstract Background Even though electronic prescribing systems are widely advocated as one of the most effective means of improving patient safety, they may also introduce new risks that are not immediately obvious. Through the study of specific incidents related to the processes involved in the administration of medication, we sought to find out if the prescribing system had unintended consequences in creating new errors. The focus of this study was a large acute hospital in the Midlands in the United Kingdom, which implemented a Prescribing, Information and Communication System (PICS). Methods This exploratory study was based on a survey of routinely collected medication incidents over five months. Data were independently reviewed by two of the investigators with a clinical pharmacology and nursing background respectively, and grouped into broad types: sociotechnical incidents (related to human interactions with the system) and non-sociotechnical incidents. Sociotechnical incidents were distinguished from the others because they occurred at the point where the system and the professional intersected and would not have occurred in the absence of the system. The day of the week and time of day that an incident occurred were tested using univariable and multivariable analyses. We acknowledge the limitations of conducting analyses of data extracted from incident reports as it is widely recognised that most medication errors are not reported and may contain inaccurate data. Interpretation of results must therefore be tentative. Results Out of a total of 485 incidents, a modest 15% (n = 73) were distinguished as sociotechnical issues and thus may be unique to hospitals that have such systems in place. These incidents were further analysed and subdivided into categories in order to identify aspects of the context which gave rise to adverse situations and possible risks to patient safety. The analysis of sociotechnical incidents by time of day and day of week indicated a trend for increased proportions of these types of incidents occurring on Sundays. Conclusion Introducing an electronic prescribing system has the potential to give rise to new types of risks to patient safety. Being aware of these types of errors is important to the clinical and technical implementers of such systems in order to, where possible, design out unintended problems, highlight training requirements, and revise clinical practice protocols.