Links

Tools

Export citation

Search in Google Scholar

Effect of sputter coating on cracking of root end surfaces after ultrasonic retrograde preparation: A SEM study of resected root apices and their respective impressions

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Question mark in circle
Preprint: policy unknown
Question mark in circle
Postprint: policy unknown
Question mark in circle
Published version: policy unknown

Abstract

The aim of this study was to evaluate in vitro the effect of sputter-coating for SEM analysis on the formation of cracks on root-end surfaces after retrograde cavity preparation with ultrasonic tips. Root-end cavities were prepared with either Satelec S12/90 degrees D diamond-coated or S12/90 degrees non-coated stainless steel retrotips. Impressions were taken before and after retrograde cavity preparation. The resected root apices and their respective impressions were examined using a scanning electron microscope, and the presence, extension and numbers of cracks were recorded after each procedure. The number of cracks observed directly on the ultrasonically prepared root-end surfaces was larger than that observed in their respective impressions taken after root-end cavity preparation, which suggests that cracking was mostly produced by the sputter-coating process required for SEM analysis. Impressions of the root-end cavities prepared with non-coated ultrasonic stainless steel retrotips showed a greater incidence of cracks (3/10 impressions) than those that replicated cavities prepared with diamond-coated retrotips (1/10 impressions). No statistical difference was found between the diamond and stainless steel retrotips.