Published in

BioMed Central, BMC Surgery, S2(13), 2013

DOI: 10.1186/1471-2482-13-s2-s47

Links

Tools

Export citation

Search in Google Scholar

Transradial approach for the endovascular treatment of type I endoleak after aortic aneurysm repair: a case report

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Abstract Background Endovascular repair of aortic aneurysms (EVAR) is obtained through the positioning of an aortic stent-graft, which excludes the aneurysmatic dilation. Type I endoleak is the most common complication, and it is caused by an incompetent proximal or distal attachment site, causing the separation between the stent-graft and the native arterial wall, and in turn creating direct communication between the aneurysm sac and the systemic arterial circulation. Endoleak occurrence is associated with high intrasac pressures, and requires a quick repair to prevent abdominal aortic aneurysm rupture. Case presentation We report the first case of a 80-year-old man undergoing percutaneous closure of a peri-graft endoleak (type I) by transcatheter embolization through radial arterial access. Conclusion The transradial approach has been shown to be a safe and effective alternative to the traditional transfemoral approach. A decrease in vascular complications and improved patient comfort are the primary benefits of this technique in patients with previous EVAR.