Published in

Cambridge University Press (CUP), Prehospital and Disaster Medicine, 05(30), p. 461-465

DOI: 10.1017/s1049023x15005038

Links

Tools

Export citation

Search in Google Scholar

Accuracy of Tympanic Temperature Measurement in Firefighters Completing a Simulated Structural Firefighting Task

Journal article published in 2015 by Toby Keene, Matt Brearley ORCID, Beth Bowen, Anthony Walker
This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

AbstractIntroductionIn the course of their duties, firefighters risk heat stroke and other medical conditions due to exertion in high-temperature environments. Infrared tympanic temperature measurement (TTym) is often used by Emergency Medical Services (EMS) to assess the core body temperature of firefighters. The accuracy of TTym in this setting has been called into question.Hypothesis/ProblemThis study aimed to examine the accuracy of TTym for core body temperature assessment at emergency firefighting events compared with gastrointestinal temperature measurement (TGI) as measured by ingestible thermometers.MethodsForty-five (42 male, three female) professional urban firefighters from an Australian fire service completed two 20-minute work periods in a 100°C (± 5°C) heat chamber while wearing personal protective clothing (PPC) and breathing apparatus (weighing approximately 22 kg). Measurements were taken immediately before entering, and on exiting, the heat chamber. Tympanic temperature was assessed by an infrared tympanic thermometer and TGI was measured by ingestible sensor and radio receiver.ResultsComplete data were available for 37 participants. Participant temperatures were higher on exiting the heat chamber than at baseline (TTym: 35.9°C (SD=0.7) vs 37.5°C (SD=0.8); TGI: 37.2°C (SD=0.4) vs 38.6°C (SD=0.5)). Tympanic temperature underestimated TGI on average by 1.3°C (SD=0.5) before entering the chamber and by 1.0°C (SD=0.8) following the exercise. Using pooled data, the average underestimation was 1.2°C (SD=0.7).ConclusionTympanic thermometers cause an unreliable measure of core body temperature for firefighters engaged in fire suppression activities. Accurate and practical measures of core body temperature are required urgently.KeeneT, BrearleyM, BowenB, WalkerA. Accuracy of tympanic temperature measurement in firefighters completing a simulated structural firefighting task. Prehosp Disaster Med. 2015;30(5):461–465.