Dissemin is shutting down on January 1st, 2025

Published in

SAGE Publications, Perfusion, 4(28), p. 350-356, 2013

DOI: 10.1177/0267659113479135

Links

Tools

Export citation

Search in Google Scholar

Minimal extracorporeal circulation reduces the incidence of postoperative major adverse events after elective coronary artery bypass grafting in high-risk patients. A single-institutional prospective randomized study

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Coronary artery bypass grafting (CABG) using minimal extracorporeal circulation (MECC) has been associated with an improved short-term clinical outcome compared to conventional extracorporeal circulation (CECC). The aim of this study was to evaluate the impact of MECC compared to CECC on postoperative major adverse events in high-risk patients undergoing elective coronary revascularization procedures. Two hundred patients undergoing elective CABG were randomized into two groups. In Group A (n=100), MECC was used while Group B (n=100) included patients who were operated on CECC. The incidence of postoperative major adverse events (myocardial infarction, renal failure, stroke, death) was the primary end-point of the study. MECC was associated with a 77% relative risk reduction in the incidence of major adverse events compared to CECC (p=0.004). The rate of major adverse events occurring in the high-risk patient subgroup (preoperative left ventricular ejection fraction ≤40%, age >65 years, EuroSCORE II >5) operated on with MECC was significantly lower in comparison to their CECC counterparts. Based on our results, cardiac centres should be encouraged to use MECC as the standard circuit when performing elective coronary procedures, even in a high-risk population.