Hemodynamic stability ensured by a low dose, low volume, unilateral hypobaric spinal block: Modification of a technique

Journal article published in 2009 by L. Elzinga, M. Marcus, D. Peek, P. Borg, J. Jansen, J. Koster, D. Enk
This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Question mark in circle
Preprint: policy unknown
Question mark in circle
Postprint: policy unknown
Question mark in circle
Published version: policy unknown

Abstract

We report the case of an 89-year-old female with a history of arterial hypertension, intermittent rapid atrial fibrillation and severe aortic valve stenosis, suffering from femoral neck fracture. Hyperbaric unilateral spinal anesthesia is a known technique to obtain stable hemodynamics combined with the possibility of continuous neurologic evaluation and preservation of cognitive functions. Because a hyperbaric unilateral technique can be very painful in case of traumatic hip fracture, a low dose, low volume, unilateral hypobaric spinal block may be an adequate alternative. In the present case report, a unilateral hypobaric spinal anesthesia was performed using 5 mg of bupivacaine in a 1.5 mL volume and a slow and steady, "air-buffered", directed injection technique, to allow an urgent hip arthroplasty. During surgery the patient was kept in the lateral recumbent position. Hemodynamics remained stable throughout the entire procedure without any need for vasoconstrictors. The impact of aortic valve stenosis combined with atrial fibrillation on anesthetic management and our considerations to opt for a unilateral hypobaric spinal anesthesia are discussed.