Published in

Sociedade Brasileira de Patologia Clínica, Jornal Brasileiro de Patologia e Medicina Laboratorial, 6(47), p. 649-654

DOI: 10.1590/s1676-24442011000600012

Links

Tools

Export citation

Search in Google Scholar

Comparação de três protocolos distintos para extração de RNA de amostras fixadas em formalina e emblocadas em parafina

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Question mark in circle
Preprint: policy unknown
Question mark in circle
Postprint: policy unknown
Question mark in circle
Published version: policy unknown
Data provided by SHERPA/RoMEO

Abstract

INTRODUCTION: Formalin fixed paraffin embedded (FFPE) tissues are an important sample source for retrospective studies. Despite its ability to preserve proteins and cell morphology, formalin hinders Molecular Biology tests once it fragments and chemically modifies nucleic acids, particularly RNA. OBJECTIVE: To compare the efficiency of three different RNA extraction protocols for gene expression analysis of FFEP tissues. MATERIAL AND METHODS: RNA was extracted from FFPE samples of human lymph by means of Ambion and Arcturus Bioscience kits and the classical Trizol method. After extraction, RNA was quantified and tested for amplification through real time polymerase chain reaction (RT-PCR) using glyceraldehydes-3 phosphate dehydrogenase (GAPDH) endogenous gene primers. DISCUSSION/CONCLUSION: All the protocols produced sufficient and adequate amounts of total RNA. However, only protocols using Arcturus and Ambion kits generated suitable RNA for PCR amplification.