Dissemin is shutting down on January 1st, 2025

Published in

Elsevier, Journal of Chromatography A, 1-2(1124), p. 82-90, 2006

DOI: 10.1016/j.chroma.2006.05.028

Links

Tools

Export citation

Search in Google Scholar

Development of Pressurized Subcritical Water Extraction Combined with Stir Bar Sorptive Extraction for the Analysis of Organochlorine Pesticides and Chlorobenzenes in Soils

Journal article published in 2006 by Rosario Rodil ORCID, Peter Popp
This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

An analytical method for the determination of several organochlorine pesticides (OCPs) like hexachlorocyclohexanes (HCHs), cyclodiene derivates (dieldrin, aldrin, endrin, heptachlor, heptachlor epoxide, endrin aldehyde, endosulfan and ensodulfan sulphate) and DDX compounds (p,p'-DDE, p,p'-DDD and p,p'-DDT) as well as chlorobenzenes in soils has been developed. The procedure is based on pressurized subcritical water extraction (PSWE) followed by stir bar sorptive extraction (SBSE) and subsequent thermodesorption-gas chromatography/mass spectrometry analysis. Significant PSWE and SBSE parameters were optimized using spiked soil and water samples. For the PSWE of the organochlorine compounds, water modified with acetonitrile as the extraction solvent, at an extraction temperature of 120 degrees C, and three cycles of 10 min extraction proved to be optimal. Under optimized conditions, the figures of merit, such as precision, accuracy and detection limits were evaluated. The detection limits obtained for soil samples were in the range 0.002-4.7 ng/g. Recoveries between 4.1 and 85.2% were achieved from samples spiked at a concentration level of 25-155 ng/g. The main advantages of this method are the avoidance of clean-up and concentration procedures as well as the significant reduction of the required volume of organic solvents. The described method was applied to the determination of the pollutants in soil samples collected from a polluted area, the Bitterfeld region (Germany). The results obtained by PSWE-SBSE were in a good agreement with those obtained by a reference method, a conventional pressurized liquid extraction (PLE).