Published in

Elsevier, Energy Procedia, (37), p. 2076-2083, 2013

DOI: 10.1016/j.egypro.2013.06.086

Links

Tools

Export citation

Search in Google Scholar

Alternative Layouts for the Carbon Capture with the Chilled Ammonia Process

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Many alternatives are being investigated for the carbon capture, but none appears to have been proved as the choice for full-scale applications. This work considers the Chilled Ammonia Process for coal-fired Ultra Super Critical power plants. Three layouts are simulated with Aspen Plus and the Extended UNIQUAC thermodynamic model. Compared to a traditional layout, stripping of the wash water of the absorber or, better, splitting the rich solution between the middle and the top of the column limits greatly the ammonia slip. Moreover, splitting the regeneration over two levels reduces substantially the electric loss due to stream extraction from the turbine. The simulations show that the net electric efficiency drops from 45.5% to 33.5-34.5%, the SPECCA index is 3.8-4.3 MJth kgCO2–1 and the heat duties are 2.7-2.9 MJth kgCO2–1. The performances may improve greatly upon optimization of the parameters.