Published in

American Heart Association, Stroke, 7(42), p. 1923-1928, 2011

DOI: 10.1161/strokeaha.110.610618

Links

Tools

Export citation

Search in Google Scholar

CT Cerebral Blood Flow Maps Optimally Correlate With Admission Diffusion-Weighted Imaging in Acute Stroke but Thresholds Vary by Postprocessing Platform

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Background and Purpose— Admission infarct core lesion size is an important determinant of management and outcome in acute (<9 hours) stroke. Our purposes were to: (1) determine the optimal CT perfusion parameter to define infarct core using various postprocessing platforms; and (2) establish the degree of variability in threshold values between these different platforms. Methods— We evaluated 48 consecutive cases with vessel occlusion and admission CT perfusion and diffusion-weighted imaging within 3 hours of each other. CT perfusion was acquired with a “second-generation” 66-second biphasic cine protocol and postprocessed using “standard” (from 2 vendors, “A-std” and “B-std”) and “delay-corrected” (from 1 vendor, “A-dc”) commercial software. Receiver operating characteristic curve analysis was performed comparing each CT perfusion parameter—both absolute and normalized to the contralateral uninvolved hemisphere—between infarcted and noninfarcted regions as defined by coregistered diffusion-weighted imaging. Results— Cerebral blood flow had the highest accuracy (receiver operating characteristic area under the curve) for all 3 platforms ( P <0.01). The maximal areas under the curve for each parameter were: absolute cerebral blood flow 0.88, cerebral blood volume 0.81, and mean transit time 0.82 and relative Cerebral blood flow 0.88, cerebral blood volume 0.83, and mean transit time 0.82. Optimal receiver operating characteristic operating point thresholds varied significantly between different platforms (Friedman test, P <0.01). Conclusions— Admission absolute and normalized “second-generation” cine acquired CT cerebral blood flow lesion volumes correlate more closely with diffusion-weighted imaging-defined infarct core than do those of CT cerebral blood volume or mean transit time. Although limited availability of diffusion-weighted imaging for some patients creates impetus to develop alternative methods of estimating core, the marked variability in quantification among different postprocessing software limits generalizability of parameter map thresholds between platforms.