Published in

American Physiological Society, American Journal of Physiology - Regulatory, Integrative and Comparative Physiology, 11(307), p. R1345-R1352, 2014

DOI: 10.1152/ajpregu.00376.2014

Links

Tools

Export citation

Search in Google Scholar

The repeated sit-to-stand maneuver is a superior method for cardiac baroreflex assessment: A comparison with the modified Oxford method and Valsalva maneuver

Journal article published in 2014 by Helen M. Horsman, Y. C. Tzeng, Duncan C. Galletly, Karen C. Peebles ORCID
This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Baroreflex assessment has diagnostic and prognostic utility in the clinical and research environments, and there is a need for a reliable, simple, noninvasive method of assessment. The repeated sit-to-stand method induces oscillatory changes in blood pressure (BP) at a desired frequency and is suitable for assessing dynamic baroreflex sensitivity (BRS). However, little is known about the reliability of this method and its ability to discern fundamental properties of the baroreflex. In this study we sought to: 1) evaluate the reliability of the sit-to-stand method for assessing BRS and compare its performance against two established methods (Oxford method and Valsalva maneuver), and 2) examine whether the frequency of the sit-to-stand method influences hysteresis. Sixteen healthy participants underwent three trials of each method. For the sit-to-stand method, which was performed at 0.1 and 0.05 Hz, BRS was quantified as an integrated response (BRSINT) and in response to falling and rising BP (BRSDOWN and BRSUP, respectively). Test retest reliability was assessed using the intraclass correlation coefficient (ICC). Irrespective of frequency, the ICC for BRSINT during the sit-to-stand method was ≥0.88. The ICC for a rising BP evoked by phenylephrine (PEGAIN) in the Oxford method was 0.78 and ≤0.5 for the remaining measures. During the sit-to-stand method, hysteresis was apparent in all participants at 0.1 Hz but was absent at 0.05 Hz. These findings indicate the sit-to-stand method is a statistically reliable BRS assessment tool and suitable for the examination of baroreflex hysteresis. Using this approach we showed that baroreflex hysteresis is a frequency-dependent phenomenon.