Published in

Lippincott, Williams & Wilkins, Therapeutic Drug Monitoring, 5(36), p. 674-676, 2014

DOI: 10.1097/ftd.0000000000000054

Links

Tools

Export citation

Search in Google Scholar

Stability of Generic Meropenem Solutions for Administration by Continuous Infusion at Normal and Elevated Temperatures

Journal article published in 2014 by Loretta Franceschi, Piergiorgio Cojutti, Massimo Baraldo, Federico Pea ORCID
This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

: Administration by continuous infusion may represent an effective tool for the treatment of multidrug-resistant gram-negative related infections with meropenem. Currently, no data on chemical stability of generic bioequivalent versions of meropenem over time are available. Triplicate samples of 5 mg/mL solutions of a generic meropenem formulation, Hospira, were evaluated for chemical stability at increasing temperatures (25°C, 30°C, 35°C, and 40°C) by means of a high-performance liquid chromatography technique over 4 separate days. Degradation of generic meropenem was both time and temperature dependent, and the aqueous solutions were stable for up to 8 hours in the temperature range between 25°C and 35°C, and for up to 5 hours at 40°C. Continuous infusion of generic meropenem Hospira may be applied in clinical settings with ambient temperature below 35°C, provided that the 5 mg/mL aqueous solution is reconstituted at most after 6-8 hours.