Published in

Elsevier, Journal of Volcanology and Geothermal Research, 1-2(198), p. 217-232

DOI: 10.1016/j.jvolgeores.2010.09.001

Links

Tools

Export citation

Search in Google Scholar

Pattern of shallow ground water flow at Mount Princeton Hot Springs, Colorado, using geoelectrical methods

Journal article published in 2 by K. Richards, A. Revil, A. Jardani, F. Henderson, M. Batzle, A. Haas
This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Red circle
Postprint: archiving forbidden
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

In geothermal fields, open faults and fractures often act as high permeability pathways bringing hydrothermal fluids to the surface from deep reservoirs. The Mount Princeton area, in south-central Colorado, is an area that has an active geothermal system related to faulting and is therefore a suitable natural laboratory to test geophysical methods. The Sawatch range-front normal fault bordering the half-graben of the Upper Arkansas valley is characterized by a right-lateral offset at Mount Princeton Hot springs. This offset is associated with the Chalk Cliffs of hydrothermally altered quartz monzonite. Because fault identification in this area is complicated by quaternary deposits (including glacial and fluvial deposits), we use DC electrical resistivity tomography and self-potential mapping to identify preferential fluid flow pathways. The geophysical data (over 5600 resistivity and 2700 self-potential measurements) provide evidence of the existence of a dextral strike slip fault zone (Fault B) responsible for the offset of the Sawatch fault. A segment of this dextral strike slip fault (termed U1) is acting as the dominant vertical flow path bringing thermal waters to a shallow unconfined aquifer. Upwelling of the thermal waters is also observed at two zones (U2 and U3) of an open fracture called Fault A. This fault is located at the tip of the Sawatch fault and is likely associated with an extensional strain regime in this area. Self-potential measurements are used to estimate the flux of upwelling thermal water. The upflow estimate (4±1×103m3/day for the open segment of the Fault B and 2±1×103m3/day for Fault A) from the geophysical data is remarkably consistent with the downstream Mt. Princeton hot water production (4.3–4.9)×103m3/day at approximately 60–86°C). A temperature map indicates that a third upwelling zone termed U4 may exist at the southern tip of the Sawatch fault.