Chemical Society of Japan, Chemistry Letters, 2(38), p. 146-147, 2009
DOI: 10.1246/cl.2009.146
Full text: Download
Thin metallic (Pd and Pt) layer was coated over inner wall of silica capillary tube (i.d. phi 0.33 min x 100cm) by electroless plating. Rapid and continuous decomposition of hydrogen peroxide (H2O2) was achieved at room temperature simply by passing the solution through the capillary.