Published in

Elsevier, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 3(602), p. 687-690

DOI: 10.1016/j.nima.2008.12.090

Links

Tools

Export citation

Search in Google Scholar

The HADES RPC Inner TOF Wall

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Red circle
Postprint: archiving forbidden
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

The upgraded HADES inner TOF Wall will cover a total area of 8 m2 with 1116 variable-geometry 4-gap, symmetric, timing RPCs, readout by 2232 time and charge channels. Each RPC is individually shielded for robust multi-hit performance and optimum use of the readout channels (crosstalk minimization). The double layer configuration provides a useful degree of redundancy for very accurate timing of a large fraction of all particles crossing the detector.In this paper we describe the concept of the detector, its inner structure and the multi-hit performance.