Published in

2008 Second International Conference on Pervasive Computing Technologies for Healthcare

DOI: 10.1109/pcthealth.2008.4571044

Thieme Gruppe, Methods of Information in Medicine

DOI: 10.3414/me9115

The Proceedings of the Second ICST International Conference on Pervasive Computing Technologies for Healthcare

DOI: 10.4108/icst.pervasivehealth2008.2522

Links

Tools

Export citation

Search in Google Scholar

An open and reconfigurable wireless sensor network for pervasive health monitoring

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Summary Objectives: Sensor networks constitute the backbone for the construction of personalized monitoring systems. Up to now, several sensor networks have been proposed for diverse pervasive healthcare applications, which are however characterized by a significant lack of open architectures, resulting in closed, non-interoperable and difficult to extend solutions. In this context, we propose an open and reconfigurable wireless sensor network (WSN) for pervasive health monitoring, with particular emphasis in its easy extension with additional sensors and functionality by incorporating embedded intelligence mechanisms. Methods: We consider a generic WSN architecture comprised of diverse sensor nodes (with communication and processing capabilities) and a mobile base unit (MBU) operating as the gateway between the sensors and the medical personnel, formulating this way a body area network (BAN). The primary focus of this work is on the intra-BAN data communication issues, adopting SensorML as the data representation mean, including the encoding of the monitoring patterns and the functionality of the sensor network. Results: In our prototype implementation two sensor nodes are emulated; one for heart rate monitoring and the other for blood glucose observations, while the MBU corresponds to a personal digital assistant (PDA) device. Java 2 Micro Edition (J2ME) is used to implement both the sensor nodes and the MBU components. Intra-BAN wireless communication relies on the Bluetooth protocol. Via an adaptive user interface in the MBU, health professionals may specify the monitoring parameters of the WSN and define the monitoring patterns of interest in terms of rules. Conclusions: This work constitutes an essential step towards the construction of open, extensible, inter - operable and intelligent WSNs for pervasive health monitoring.