Abstract

An outbreak of Pseudomonas fluorescens infection in six patients in a coronary care unit was associated with a source not previously reported, namely the ice bath used for cardiac output determinations. Outbreaks of pseudobacteraemia caused by P. fluorescens and occasional blood transfusion-associated bloodstream infection (BSI) have been described. However, during the last two decades, two outbreaks of P. fluorescens BSI have been described and this article reports a third. Isolation of P. fluorescens in blood cultures must alert clinicians to the possibility of contamination of infusate, lock solutions or catheter flush.