Published in

Elsevier, Food Microbiology, 6(27), p. 835-840, 2010

DOI: 10.1016/j.fm.2010.05.002

Links

Tools

Export citation

Search in Google Scholar

Inactivation of Escherichia coli by ozone treatment of apple juice at different pH levels

Journal article published in 2010 by S. Patil, V. P. Valdramidis, P. J. Cullen ORCID, J. Frias, P. Bourke ORCID
This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

This research investigated the efficacy of gaseous ozone on the inactivation of Escherichia coli ATCC 25922 and NCTC 12900 strains in apple juice of a range of pH levels, using an ozone bubble column. The pH levels investigated were 3.0, 3.5, 4.0, 4.5 and 5.0. Apple juice inoculated with E. coli strains (10(6)CFU/mL) was treated with ozone gas at a flow rate of 0.12L/min and ozone concentration of 0.048 mg/min/mL for up to 18 min. Results show that inactivation kinetics of E. coli by ozone were affected by pH of the juice. The ozone treatment duration required for achieving a 5-log reduction was faster (4 min) at the lowest pH than at the highest pH (18 min) studied. The relationship between time required to achieve 5log reduction (t(5d)) and pH for both strains was described mathematically by two exponential equations. Ozone treatment appears to be an effective process for reducing bacteria in apple juice and the required applied treatment for producing a safe apple juice is dependant on its acidity level.