Published in

Elsevier, Surface and Coatings Technology, (233), p. 119-130, 2013

DOI: 10.1016/j.surfcoat.2013.04.015

Links

Tools

Export citation

Search in Google Scholar

An overview on diamond-like carbon coatings in medical applications

Journal article published in 2013 by Roland Hauert ORCID, Kerstin Thorwarth, Götz Thorwarth
This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

This overviewarticle on diamond-like carbon (DLC) coatings in medical applications covers the interaction of cells and tissuewith DLC and alloyed DLC to generate desired cell reactions as well as the release of toxic elements. The promising in vitro results of DLC to prevent thrombus formation in vascular applications are summarized and the problems of transferring these results to in vivo applications are described. SinceDLC shows extremely lowwear in technical applications, a desired implementation is also to build wear particle free, articulating joint replacements by coating the bearing surfaces. Several in vivo studies using DLC coatings on articulating joints resulted in a failure due to partial coating delamination some years after implantation. It will be shown that this delayed delamination was caused by crevice corrosion (CC) of the adhesion-promoting interlayer and the reasonwhy different corrosion processes may prevent an easy transfer of a successful technical application of DLC onto an implant will be discussed. The main issue for successful, long-term, in vivo applications of DLC coatings on implants is to predict the in vivo survival time and especially the long-termadhesion stability of the coating. The formation at the interface of a few atomic layers of reaction products, usually a metal-carbide,will be addressed. Furthermore, any contamination from residual gas or any cross contamination will result in a different reactively formed interface material with different properties. Delamination can then occur by a slowly advancing crack in this thin carbidic layer governed by the laws of stress corrosion cracking (SCC). It will be shown that if a stable coating adhesion is obtained, DLC coated articulating implants show basically no wear of the coating up to 101 million articulations on a simulator corresponding to about 101 years of in vivo articulation.