Taylor and Francis Group, Desalination and Water Treatment, 1-3(26), p. 87-91
Full text: Download
2011): Remediation of oily wastewater from an interceptor tank using a novel photocatalytic drum reactor, Desalination and Water Treatment, 26:1-3, 87-91 A novel photocatalytic reactor has been developed to remediate oily wastewaters. In the fi rst instance degradation rates of model organic compounds, methylene blue (MB) and 4-c hlorophenol (4-CP) were determined. The experimental set-up investigated a 1:10 w/v cata-lyst to organic solution volume, 30 g catalyst, 300 mls MB (10 μM) or 4-CP (100 μM). The cata-lyst investigated was a pellet catalyst to improve separation of the remediated volume from the catalyst following treatment. MB concentration decreased by 93% after 15 mins irradiation whilst 4-CP concentration decreased by 94% following 90 mins irradiation. Oily waste water (OWW) from an interceptor tank typically containing diesel oils was obtained from Sureclean, an environmental clean-up company. The OWW was treated using the same conditions as MB and 4-CP, the model organic compounds. Levels of total organic carbon (TOC) and total petroleum hydrocarbon (TPH) were used to monitor the effi cacy of the photocatalytic reactor. TOC reduced by 45% following two 90 mins treatment cycles. TPH reduced by 45% following 90 mins irradiation and by a further 25% during a second stage of treatment. This reactor can be used as a polishing technique assembled within a wastewater treatment plant. Allowing for more than one pass through the reactor improves its effi ciency.