Published in

NIHR Journals Library, Health Technology Assessment, 23(19), p. 1-178, 2015

DOI: 10.3310/hta19230

Links

Tools

Export citation

Search in Google Scholar

A randomised controlled trial and cost-effectiveness analysis of high-frequency oscillatory ventilation against conventional artificial ventilation for adults with acute respiratory distress syndrome. The OSCAR (OSCillation in ARDS) study

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Red circle
Preprint: archiving forbidden
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

BackgroundPatients with the acute respiratory distress syndrome (ARDS) require artificial ventilation but this treatment may produce secondary lung damage. High-frequency oscillatory ventilation (HFOV) may reduce this damage.ObjectivesTo determine the clinical benefit and cost-effectiveness of HFOV in patients with ARDS compared with standard mechanical ventilation.DesignA parallel, randomised, unblinded clinical trial.SettingUK intensive care units.ParticipantsMechanically ventilated patients with a partial pressure of oxygen in arterial blood/fractional concentration of inspired oxygen (P : F) ratio of 26.7 kPa (200 mmHg) or less and an expected duration of ventilation of at least 2 days at recruitment.InterventionsTreatment arm HFOV using a Novalung R100®ventilator (Metran Co. Ltd, Saitama, Japan) ventilator until the start of weaning.Control arm Conventional mechanical ventilation using the devices available in the participating centres.Main outcome measuresThe primary clinical outcome was all-cause mortality at 30 days after randomisation. The primary health economic outcome was the cost per quality-adjusted life-year (QALY) gained.ResultsOne hundred and sixty-six of 398 patients (41.7%) randomised to the HFOV group and 163 of 397 patients (41.1%) randomised to the conventional mechanical ventilation group died within 30 days of randomisation (p = 0.85), for an absolute difference of 0.6% [95% confidence interval (CI) −6.1% to 7.5%]. After adjustment for study centre, sex, Acute Physiology and Chronic Health Evaluation II score, and the initial P : F ratio, the odds ratio for survival in the conventional ventilation group was 1.03 (95% CI 0.75 to 1.40;p = 0.87 logistic regression). Survival analysis showed no difference in the probability of survival up to 12 months after randomisation. The average QALY at 1 year in the HFOV group was 0.302 compared to 0.246. This gives an incremental cost-effectiveness ratio (ICER) for the cost to society per QALY of £88,790 and an ICER for the cost to the NHS per QALY of £78,260.ConclusionsThe use of HFOV had no effect on 30-day mortality in adult patients undergoing mechanical ventilation for ARDS and no economic advantage. We suggest that further research into avoiding ventilator-induced lung injury should concentrate on ventilatory strategies other than HFOV.Trial registrationCurrent Controlled Trials ISRCTN10416500.FundingThis project was funded by the NIHR Health Technology Assessment programme and will be published in full inHealth Technology Assessment; Vol. 19, No. 23. See the NIHR Journals Library website for further project information.