Published in

IOP Publishing, Japanese Journal of Applied Physics, 3(47), p. 1717-1722, 2008

DOI: 10.1143/jjap.47.1717

Links

Tools

Export citation

Search in Google Scholar

Characterization of Sensitivity and Resolution of Silicon Resistive Probe

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

The resistive probe, which can detect the variation in probe resistance while scanning over positive/negative biased bits, has been considered as the one of the most suitable candidate for used as a high-speed, ultralarge-storage systems. Ultralarge-storage density has been demonstrated by the electrical recording technique in which surface charge is read in ferroelectric materials, which is named as scanning resistive probe microscopy (SRPM). Because of the difficulty of fabricating, the SRPM device little has been previously done on relating probe properties with process parameters. As it is important in probe design to analyze the properties of sensitivity and resolution for different process and device parameters, the parameters of the fabricated microscope are embedded in the simulation performed in this study. To obtain the optimum resistive probe design, we analyze the effect of different process parameters on the properties. In the first part of the paper, the device structure fabricated to identify the electrostatic charge effects between the tip and the poly silicon domain (surface) is presented. In the second part, we explain the process conditions of the resistive probe. In the third part, we present the sensitivity and resolution for different process conditions. The probe is placed in contact with a poly silicon domain (surface) to measure the field sensitivity, and a 0.3% resistance change per voltage applied to the surface is detected with a spatial resolution of less than 1000 nm. The sensitivity and resolution for different implantation doses, wet oxidation time, and resistances in the high-doped n-type region are also presented. We found that there is a correlation between sensitivity and resolution for different implantation doses and annealing times. Although the sensitivity decreases as resistance increases, the change is less than 10% even at a resistance of 200 Omega. Therefore, the resistance of the cantilever can be neglected in our study of probe sensitivity.