Published in

Wiley, Magnetic Resonance in Medicine, 3(50), p. 614-622, 2003

DOI: 10.1002/mrm.10567

Links

Tools

Export citation

Search in Google Scholar

Model of the human vasculature for studying the influence of contrast injection speed on cerebral perfusion MRI

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Simulations of dynamic susceptibility contrast (DSC) MRI are frequently performed by assuming a certain shape for the input function and the microvascular response function. However, to investigate the influence of parameters that will affect the shape of the input function, a more complex model of the human vasculature is required. In this study, a model of the human vasculature is proposed that consists of a network of vascular operators based on physiological data typical of a 35-year-old male subject. The simulated contrast passage curves were found to be within the range of observed contrast passage curves in a population of patients without vascular disease. The model was used to predict the effect of different injection speeds of the contrast agent on the accuracy of the perfusion experiment. It was found that injection speeds of <3 ml/s lead to an underestimation of the observed cerebral blood flow (CBF). Additionally, it was determined that decreasing the temporal resolution of the acquisition results in an underestimation of the CBF values, and an increase of the standard deviation (SD) of CBF measurements.