Published in

Radiological Society of North America, Radiology, 2(233), p. 603-608

DOI: 10.1148/radiol.2332030884

Links

Tools

Export citation

Search in Google Scholar

Supratentorial Cerebrospinal Fluid Production Rate in Healthy Adults: Quantification with Two-dimensional Cine Phase-Contrast MR Imaging with High Temporal and Spatial Resolution

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Red circle
Preprint: archiving forbidden
Green circle
Postprint: archiving allowed
Orange circle
Published version: archiving restricted
Data provided by SHERPA/RoMEO

Abstract

A method for objectively determining supratentorial cerebrospinal fluid (CSF) production rate is described. The method employs cine phase-contrast magnetic resonance imaging with high temporal and spatial resolution at the level of the aqueduct of Sylvius. Automatic encircling of the aqueduct was accomplished by using a pulsatility-based segmentation approach. Results in 23 healthy adults (18 men, five women; age range, 21-39 years) yielded an average CSF production rate of 305 microL/min +/- 145 (standard deviation); this rate is in good agreement with literature-reported values obtained with invasive ventriculolumbar perfusion measurements. Average operator imprecision was 23.1% if automatic segmentation was not used. The proposed method is potentially an effective means for measuring supratentorial CSF production rate in humans.