Published in

Portland Press, Clinical Science, 2(102), p. 127-134, 2002

DOI: 10.1042/cs1020127

Portland Press, Clinical Science, 2(102), p. 127, 2002

DOI: 10.1042/cs20010051

Links

Tools

Export citation

Search in Google Scholar

Quantification of right-to-left shunt with 99mTc-labelled albumin macroaggregates and 100% oxygen in patients with hereditary haemorrhagic telangiectasia

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Red circle
Preprint: archiving forbidden
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Pulmonary arteriovenous malformations (PAVMs) are often associated with hereditary haemorrhagic telangiectasia (HHT). The quantification of right-to-left shunts in patients with PAVMs is important in diagnosis and follow up. Traditionally, this shunt is measured by the 100% oxygen method, in which the value for the arteriovenous difference in oxygen content, Cao(2)-C (v) over baro(2) (where Cao(2) is the oxygen content of arterial blood and C (v) over baro(2) is the oxygen content of mixed venous blood) is estimated. Alternative methods consist of measurement of the systemic or renal uptake of Tc-99m-labelled macroaggregates of albumin (MAA), which are trapped in pulmonary capillaries, but pass through PAVMs. We first measured Cao(2)-C (v) over bar (2) in 12 HHT patients before and after embolization of PAVMs. We obtained a mean value of 4.4 ml/100 ml, instead of the usual 5 ml/100 ml. Subsequently, we measured right-to-left shunt in 21 HHT patients using the 100% oxygen method and with two different methods involving Tc-99m. We used the kidney-lung method (K/L method), in which it is assumed that the right kidney receives 10% of the cardiac output, and we also used a method with two tracers (HSA/MAA method): (1) Tc-99m-labelled human serum albumin (HSA) (which passes through pulmonary capillaries) to measure the fraction of the cardiac output perfusing the kidneys, and (2) MAA to measure the shunt fraction. In 35 shunt measurements we evaluated this new technique and the K/L method, by comparing the results with those from the 100% oxygen method. There was poor agreement between the 100% oxygen method and the K/L method, with 95% limits of agreement for the shunt fraction of - 15.2% to + 15.2%. There was moderate agreement between the 100% oxygen method and the HSA/MAA method, with limits of agreement of -8.3% to +7.7%. We conclude that the different methods cannot replace each other, because the limits of agreement are too wide for clinical use.