Published in

Elsevier, Tunnelling and Underground Space Technology, (47), p. 200-210, 2015

DOI: 10.1016/j.tust.2015.01.006

Links

Tools

Export citation

Search in Google Scholar

Design of FRC tunnel segments considering the ductility requirements of the Model Code 2010

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Fibre reinforced concrete (FRC) is used to improve the mechanical response of precast segments for tunnels. The structural use of the material has been regulated by national codes and, recently, by the Model Code 2010 (MC 2010, hereinafter). In this regard, it is necessary to update the philosophy applied to the design of tunnel segments in compliance with the most recent guidelines, evaluating their applicability and repercussion. The objective of this paper is to present a critical analysis of the design of FRC segments according to the ductility requirements from the MC 2010; an alternative approach is proposed that is compatible with the condition found in some tunnels. The repercussions of both approaches are evaluated for the Metro Line 9 from Barcelona using results obtained in an experimental program with fullscale segments. The study suggests that the alternative approach may be applied under certain conditions, leading to a reduction in the fibre consumption. ; Peer Reviewed ; Postprint (author’s final draft)