Published in

Lippincott, Williams & Wilkins, Transplantation, 10(98), p. 1112-1118, 2014

DOI: 10.1097/tp.0000000000000186

Links

Tools

Export citation

Search in Google Scholar

Prediction of death in less than 60 minutes after withdrawal of cardiorespiratory support in potential organ donors after circulatory death

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Background: Given the stable number of potential organ donors after brain death, donors after circulatory death have been an increasing source of organs procured for transplant. Among the most important considerations for donation after circulatory death (DCD) is the prediction that death will occur within a reasonable period of time after the withdrawal of cardiorespiratory support (WCRS). Accurate prediction of time to death is necessary for the procurement process. We aimed to develop simple predictive rules for death in less than 60 min and test the accuracy of these rules in a pool of potential DCD donors. Methods: A multicenter prospective longitudinal cohort design of DCD eligible patients (n=318), with the primary binary outcome being death in less than 60 min after withdrawal of cardiorespiratory support conducted in 28 accredited intensive care units (ICUs) in Australia. We used a random split-half method to produce two samples, first to develop the predictive classification rules and then to estimate accuracy in an independent sample. Results: The best classification model used only three simple classification rules to produce an overall efficiency of 0.79 (0.72-0.85), sensitivity of 0.82 (0.73-0.90), and a positive predictive value of 0.80 (0.70-0.87) in the independent sample. Using only intensive care unit specialist prediction (a single classification rule) produced comparable efficiency 0.80 (0.73-0.86), sensitivity 0.87 (0.78-0.93), and positive predictive value 0.78 (0.68-0.86). Conclusion: This best predictive model missed only 18% of all potential donors. A positive prediction would be incorrect on only 20% of occasions, meaning there is an acceptable level of lost opportunity costs involved in the unnecessary assembly of transplantation teams and theatres.